What we do
Specification through
to twenty-year service.
From 500 VA single-phase rack UPS up to 2 MVA three-phase modular arrays, UPS Services covers the full critical-power lifecycle: design, installation, commissioning, preventative maintenance, battery replacement, and end-to-end project delivery.
16+
Years operating
1,200+
Projects delivered
500 VA–2 MVA
Capacity range
Australia-wide
Service area
Installation
Fully licensed UPS installation from 500 VA single-phase to 2 MVA three-phase, including commissioning, load bank testing, and SAT documentation.
- 01→
Single-Phase UPS Installation
Licensed UPS installation for server rooms, healthcare, retail and small data halls, 500VA to 20kVA.
- AS/NZS 3000:2018Wiring Rules
- AS IEC 62040.1UPS systems – General and safety requirements
- AS/NZS 5139:2019Battery systems – Electrical installations
- AS/NZS 3008.1.1Cable selection
→ - 02→
Three-Phase UPS Installation
Licensed three-phase UPS installation for data centres, hospitals, mining sites and large industrial loads, 10kVA to 2MVA.
- AS/NZS 3000:2018Wiring Rules
- AS IEC 62040.1UPS – Safety requirements
- AS IEC 62040.3UPS – Performance requirements
- AS/NZS 5139:2019Battery systems – Electrical installations
- AS/NZS 3008.1.1Cable selection
- AS/NZS 4836Safe working on low-voltage electrical installations
→ - 05→
UPS Commissioning
Manufacturer-aligned commissioning, load bank testing, and SAT documentation for new and refit UPS installations.
- AS IEC 62040.3UPS – Performance requirements
- IEEE 446Recommended practice for emergency/standby power
- AS/NZS 4836Safe working on low-voltage electrical installations
→ - 10→
Data Centre UPS Installation
Specialist UPS installation for colocation, hyperscale and enterprise data centres. N+1 and 2N redundancy. AS IEC 62040 compliant.
- AS IEC 62040-1:2019UPS systems, General and safety requirements
- AS/NZS 3000:2018Wiring Rules
- AS/NZS 5139:2019Battery systems, Electrical installations
- TIA-942-BTelecommunications Infrastructure Standard for Data Centres
→
Maintenance
Preventative maintenance contracts, battery impedance testing, thermal imaging, and complete battery replacement programmes.
- 03→
UPS Maintenance
Preventative UPS maintenance contracts: annual, bi-annual, and 24/7 emergency response across Australia.
- AS IEC 62040.1UPS – Safety requirements
- AS/NZS 4836Safe working on low-voltage electrical installations
- AS 4836 / IEEE 1188VRLA battery maintenance
- AS/NZS 5139:2019Battery systems – Electrical installations
→ - 04→
UPS Battery Replacement
VRLA, AGM, and lithium-ion UPS battery replacement: supply, install, dispose, certify.
- AS/NZS 5139:2019Battery systems – Electrical installations
- IEEE 1188VRLA battery maintenance and testing
- AS/NZS 4836Safe working on low-voltage electrical installations
→ - 11→
Emergency UPS Callout
24/7 emergency UPS breakdown response. 4-hour SLA available for critical sites across Brisbane, Sydney, Melbourne and national.
- AS IEC 62040-1:2019UPS systems, General and safety requirements
- AS/NZS 3000:2018Wiring Rules
→
Consulting
Power-quality surveys, harmonic analysis, and end-to-end critical power design from concept to project delivery.
- 06→
Power Integrity Inspection
Power-quality survey, harmonic analysis, earth-loop integrity and transient capture for critical sites.
- AS/NZS 61000.4.30Power quality measurement methods
- AS/NZS 61000.3.2 / 3.4Harmonic emission limits
- AS/NZS 3760In-service safety inspection
→ - 07→
UPS Design & Deployment
End-to-end critical power design: sizing, redundancy, switchgear, generator integration and project delivery.
- AS/NZS 3000:2018Wiring Rules
- AS IEC 62040.3UPS – Performance requirements
- AS/NZS 5139:2019Battery systems
- AS/NZS 3010Generating sets
- AS/NZS 4777.2Grid-connect inverters
- IEEE 446Emergency and standby power systems
→ - 08→
Battery Room Gas Detection
Hydrogen, off-gassing, refrigerant and ammonia detection for VRLA, lithium-ion and BESS battery rooms — design, supply, install and certify.
- AS/NZS 5139:2019Battery systems
- AS/NZS 60079.10.1Hazardous area classification
- AS 1851Routine service of fire protection systems
- AS/NZS 4761Competencies for working with hazardous substances
- FPA Australia GPG-04Lithium-ion battery fire safety
- AS/NZS IEC 62485Battery installation safety
→ - 09→
Critical Power Services
End-to-end critical power solutions for data centres, hospitals, government and mining. Design, install, maintain.
- AS IEC 62040-1:2019UPS systems, General and safety requirements
- AS/NZS 3000:2018Wiring Rules
- AS 3003:2018Electrical installations, Patient areas
- AS/NZS 5139:2019Battery systems, Electrical installations
→ - 12→
UPS Hire & Rental
Temporary UPS hire for planned outages, construction sites, events and emergency cover. Single-phase and three-phase units available nationwide.
- AS IEC 62040-1:2019UPS systems, General and safety requirements
- AS/NZS 3000:2018Wiring Rules
→
Monitoring
24/7 remote monitoring of UPS systems, battery health, power quality and environmental conditions with cloud dashboards and predictive alerts.
Talk to a specialist
When power is critical, the conversation begins with a phone call.
Our engineers scope your requirement, recommend the right approach, and provide a written quote, typically within one business day.
24/7 Critical line
1800 046 344Emergency response available around the clock for maintenance contract customers.